Weighing electronics
Connection to scales with analog strain gauge load cells, entry impedance 43 Ohm–3.3 kOhm (e.g. suitable for 8 x 350 Ohm load cells), or via zener barriers, entry impedance 87.5 Ohm–3.3 kOhm (e.g. suitable for 4 x 350 Ohm load cells), W&M approved resolution of up to 6,000 d at a max. of 80 % preload, internal resolution 524,000 d, update rate selectable 50–800 updates / second, smallest load cell signal 0.33 mV/e. Optional connection of two scale bases via DUAL-ADM. Option: connection of scale platforms with digital force transducers.
Calibration
Cleartext operator prompting. Setup as single or multiple range scale with 1, 2 or 3 ranges or as multi-interval scale. Calibration with test weights or through entry of rated output of load cell(s), option for the linearization of the load curve with up to 6 linearization points. Option to connect incline switch.
Electrical connection
110 (–15 %) to 240 (+10 %) V AC, 50/60 Hz via external power supply unit, option: 12–30 V DC, power consumption max. 20 VA.
Operating temperature
–10 °C (+14 °F) to +40 °C (+104 °F), max. 95 % relative humidity, non-condensing. Display and keyboard Bright, high-contrast 7″ color TFT display, 800 x 480 pixel, with wide viewing angel, large weight display and 4 to 8 input lines. Touchpanel operation.
Serial interfaces
Up to 2 interfaces, selectable RS232, 20mA CL (passive), RS422 or RS485 for label printers, precision scales, remote displays, transponder card readers, etc.
Parallel and analog I/Os
Up to 4 internal optoisolated inputs and outputs, 24 V DC, or external relay/transistor module (64 inputs, 64 outputs max.). Internal 15-bit analog output, an external module for up to 4 analog inputs/outputs as an option.
Ethernet interface
10/100 Mbit Ethernet interface with integrated web server, WLAN as option, Modbus TCP Slave as an option.
USB
USB 2.0 host interface with an optional IP65 connector for PC keyboard, scanner or USB stick.
Security
Power-fail-safe storage of data, password protection, battery-backed real-time clock, remote diagnosis over Ethernet / Internet possible.
CPU / operating system
32-bit ARM processor, 266 MHz, 0.5 MB data memory, expandable. Linux based real-time multitasking operating system.
Free programmability
Comprehensive, PC-based program development and test environment. Programming with RTC WIN in ‘C’ in compliance with WELMEC software guidelines. Complete software development and test/simulation possible on PC.
Options
RTC WIN
IT6000ET programming environment.
PC COM+